H07RN-F Neoprene cable
The H07RN-F cables are designed to supply power to low voltage equipment, including electric motors, machines, generators and generators. Thanks to their exceptional flexibility and mechanical strength, H07RN-F cables are ideal for power transmission in both fixed installations and mobile applications. The cables are wear-resistant and resistant to oils and various weather conditions, and are therefore ideal for use in construction and workshops.
What does H07RN-F stand for
The 'H' in H07RN-F stands for harmonization, which means that the specifications of this cable are standardized according to the HAR standards and European standards. The '07' indicates that the cable voltage is 450/750 volts. 'RN' stands for rubber jacket, which indicates that the jacket is made of rubber material.
The 'F' stands for flexible, which indicates that the cable is flexible and bendable.
Some Features of the H07RN-F
- The cable is chemical and oil resistant.
- The material of the jacket is neoprene (rubber).
- The cable operates within a voltage of 450/750V.
- The cable is water resistant.
- The cable has been harmonized and complies with a HAR quality mark.
- The cable is suitable for temperatures between -40 and +90 degrees Celsius.
- The cable is wear-resistant
For large projects, we deliver large reels on location and we can, in consultation with production, print the cable with a specifically requested print.
The cable is in stock from single-core to multi-core and we can of course supply the required length and size.
Sections of 10 meters for power cables or volumes of 500 meters of reels are possible with us at no extra cost.
You can also contact us for the assembly of extension cables, please feel free to do so contact us.
For more specifications see the datasheet below.
Offer
1x16mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
1x25mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
1x35mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
1x50mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
2×1.5mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
2×2.5mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
3G1.5mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
3G2.5mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
3G4.0mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
3G6.0mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
4G1.5mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |
4G2.5mm2 H07RN-F Black
Conductor | Flexible Class 5 bare copper |
---|---|
outer sheath | Rubber |
temperature range | Fixed Installation – 25 °C / + 55 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | Eca |
IEC / EN standard | EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2 |