1–16 of 18 products found
-
Solar cable (H1Z2Z2-K) CCA Blue 10mm2
Conductor Class 5 flexible tinned copper
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Cca-s1,d2,a1, according to EN 50575
IEC / EN standard EN 50618, IEC 62930, UTE C 32-502
-
Solar cable (H1Z2Z2-K) CCA Blue 4.0mm2
Conductor Class 5 flexible tinned copper
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Cca-s1,d2,a1, according to EN 50575
IEC / EN standard EN 50618, IEC 62930, UTE C 32-502
-
Solar cable (H1Z2Z2-K) CCA Blue 6.0mm2
Conductor Class 5 flexible tinned copper
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Cca-s1,d2,a1, according to EN 50575
IEC / EN standard EN 50618, IEC 62930, UTE C 32-502
-
Solar cable (H1Z2Z2-K) CCA Red 10mm2
Conductor Class 5 flexible tinned copper
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Cca-s1,d2,a1, according to EN 50575
IEC / EN standard EN 50618, IEC 62930, UTE C 32-502
-
Solar cable (H1Z2Z2-K) CCA Red 4.0mm2
Conductor Class 5 flexible tinned copper
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Cca-s1,d2,a1, according to EN 50575
IEC / EN standard EN 50618, IEC 62930, UTE C 32-502
-
Solar cable (H1Z2Z2-K) CCA Red 6.0mm2
Conductor Class 5 flexible tinned copper
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Cca-s1,d2,a1, according to EN 50575
IEC / EN standard EN 50618, IEC 62930, UTE C 32-502
-
Solar cable (H1Z2Z2-K) CCA Black 10mm2
Conductor Class 5 flexible tinned copper
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Cca-s1,d2,a1, according to EN 50575
IEC / EN standard EN 50618, IEC 62930, UTE C 32-502
-
Solar cable (H1Z2Z2-K) CCA Black 4,0mm2
Conductor Class 5 flexible tinned copper
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Cca-s1,d2,a1, according to EN 50575
IEC / EN standard EN 50618, IEC 62930, UTE C 32-502
-
Solar cable (H1Z2Z2-K) CCA Black 6,0mm2
Conductor Class 5 flexible tinned copper
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Cca-s1,d2,a1, according to EN 50575
IEC / EN standard EN 50618, IEC 62930, UTE C 32-502
-
Solar cable (H1Z2Z2-K) DCA Blue 10mm2
Conductor Twisted flexible tinned copper conductor
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Dca-s2, d2, a1
IEC / EN standard EN 50618:2014, IEC 60228, EN 50395, EN 50396, EN 60332-1-2,
EN 61034-1/2, EN 50525-1, EN 60216-1/2 -
Solar cable (H1Z2Z2-K) DCA Blue 4.0mm2
Conductor Twisted flexible tinned copper conductor
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Dca-s2, d2, a1
IEC / EN standard EN 50618:2014, IEC 60228, EN 50395, EN 50396, EN 60332-1-2,
EN 61034-1/2, EN 50525-1, EN 60216-1/2 -
Solar cable (H1Z2Z2-K) DCA Blue 6.0mm2
Conductor Twisted flexible tinned copper conductor
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Dca-s2, d2, a1
IEC / EN standard EN 50618:2014, IEC 60228, EN 50395, EN 50396, EN 60332-1-2,
EN 61034-1/2, EN 50525-1, EN 60216-1/2 -
Solar cable (H1Z2Z2-K) DCA Red 10mm2
Conductor Twisted flexible tinned copper conductor
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Dca-s2, d2, a1
IEC / EN standard EN 50618:2014, IEC 60228, EN 50395, EN 50396, EN 60332-1-2,
EN 61034-1/2, EN 50525-1, EN 60216-1/2 -
Solar cable (H1Z2Z2-K) DCA Red 4.0mm2
Conductor Twisted flexible tinned copper conductor
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Dca-s2, d2, a1
IEC / EN standard EN 50618:2014, IEC 60228, EN 50395, EN 50396, EN 60332-1-2,
EN 61034-1/2, EN 50525-1, EN 60216-1/2 -
Solar cable (H1Z2Z2-K) DCA Red 6.0mm2
Conductor Twisted flexible tinned copper conductor
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Dca-s2, d2, a1
IEC / EN standard EN 50618:2014, IEC 60228, EN 50395, EN 50396, EN 60332-1-2,
EN 61034-1/2, EN 50525-1, EN 60216-1/2 -
Solar cable (H1Z2Z2-K) DCA Black 10mm2
Conductor Twisted flexible tinned copper conductor
Outer Sheath LSZH
temperature range -40 / + 120 ° C
Nominal Voltage Uo/U 1.0/1.0 kV AC – 1.5/1.5 kV DC
UV resistant Yes
CPR Class Dca-s2, d2, a1
IEC / EN standard EN 50618:2014, IEC 60228, EN 50395, EN 50396, EN 60332-1-2,
EN 61034-1/2, EN 50525-1, EN 60216-1/2