113–128 van de 275 producten gevonden
-
2×2.5mm2 H07RN-F Black
Conductor Flexible Class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2
-
2×2.5mm2 Ymvkas Grey DCA
Conductor Bare solid copper wire ( Class 1 ) or larger sections stranded (Class 2 )
outer-sheath PVC mb
Temperature range Fixed Installation -20 °C / + 90 °C
nominal-voltage-uo-u 0.6/1Kv
UV resistant Yes
CPR class Dca
IEC / EN standard EN 50575 / EN50399 / EN60332-3-24
-
2x25mm2 H07RN-F Black
Conductor Flexible Class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2
-
2x2x0,80+0,80mm JE-H(st)H – Bd FE180 / E30-E90 Orange B2CA
Conductor Bare solid copper wire ( Class 1 )
outer-sheath LSZH
Temperature range Fixed Installation – 30 °C / + 70 °C
UV resistant No
CPR class B2CA
IEC / EN standard EN 61034 / EN 50267 / IEC 60332-3-24 Cat C
-
2x2x0,80+0,80mm JE-H(st)H – RED CCA
Conductor Bare solid copper wire ( Class 1 )
outer-sheath LSZH
Temperature range Fixed Installation – 30 °C / + 70 °C
UV resistant No
CPR class CCA
IEC / EN standard EN 60332-3-24 Cat C / EN 61034-2 / EN 60754-2 /
-
2x2x0.34mm2 Li2YCYv Black
Conductor Bare copper stranded.
outer-sheath Polyvethylene (PE)(2Y)
Temperature range Fixed Installation – 15 °C / + 70 °C
nominal-voltage-uo-u 300 / 500 V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 60228 / EN50575
-
2x2x0.5mm2 Li2YCYv Black
Conductor Bare copper stranded.
outer-sheath Polyvethylene (PE)(2Y)
Temperature range Fixed Installation – 15 °C / + 70 °C
nominal-voltage-uo-u 300 / 500 V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 60228 / EN50575
-
2x2x1.0mm2 Li2YCYv Black
Conductor Bare copper stranded.
outer-sheath Polyvethylene (PE)(2Y)
Temperature range Fixed Installation – 15 °C / + 70 °C
nominal-voltage-uo-u 300 / 500 V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 60228 / EN50575
-
2x35mm2 H07RN-F Black
Conductor Flexible Class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2
-
2×4.0 mm2 Ymvkas Grey DCA
Conductor Bare solid copper wire ( Class 1 ) or larger sections stranded (Class 2 )
outer-sheath PVC mb
Temperature range Fixed Installation -20 °C / + 90 °C
nominal-voltage-uo-u 0.6/1Kv
UV resistant Yes
CPR class Dca
IEC / EN standard EN 50575 / EN50399 / EN60332-3-24
-
2×4.0mm2 H07RN-F Black
Conductor Flexible Class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2
-
2x50mm2 H07RN-F Black
Conductor Flexible Class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2
-
2×6.0mm2 H07RN-F Black
Conductor Flexible Class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2
-
2×6.0mm2 Ymvkas Grey DCA
Conductor Bare solid copper wire ( Class 1 ) or larger sections stranded (Class 2 )
outer-sheath PVC mb
Temperature range Fixed Installation -20 °C / + 90 °C
nominal-voltage-uo-u 0.6/1Kv
UV resistant Yes
CPR class Dca
IEC / EN standard EN 50575 / EN50399 / EN60332-3-24
-
2x70mm2 H07RN-F Black
Conductor Flexible Class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2
-
3G0.75mm2 H05RR-F Black
Conductor Flexible class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 300/500V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 60228 / EN60332-1-2 /