81–96 van de 275 producten gevonden
-
1×6.0mm2 H07Z1-R Green/Yellow B2CA
Conductor Stranded Class 2 bare copper
outer-sheath LSZH
Temperature range Fixed Installation – 20 °C / + 70 °C
nominal-voltage-uo-u 450/750V
UV resistant No
CPR class B2CA
IEC / EN standard EN 60228 / EN 50363-7 / EN13501-6 /
-
1×6.0mm2 H1Z2Z2-K DCA 1 meter ( Assembled ) staubli MC4
-
1×6.0mm2 H1Z2Z2-K DCA 2 meter ( Assembled ) staubli MC4
-
1x630mm2 H07RN-F Black
Conductor Flexible Class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2
-
1x630mm2 H07Z1-R Green/Yellow B2CA
Conductor Stranded Class 2 bare copper
outer-sheath LSZH
Temperature range Fixed Installation – 20 °C / + 70 °C
nominal-voltage-uo-u 450/750V
UV resistant No
CPR class B2CA
IEC / EN standard EN 60228 / EN 50363-7 / EN13501-6 /
-
1x6mm2 H07Z-R Blue
Conductor Stranded Class 2 bare copper
outer-sheath LSZH
Temperature range Fixed Installation – 5 °C / + 70 °C
nominal-voltage-uo-u 450/750V
UV resistant No
CPR class Eca
IEC / EN standard EN 50525-3-31 / IEC 60332-1-2 / EN 50267
-
1x6mm2 H07Z1-K Green/Yellow Tinned and UV resistant B2CA
Conductor Flexible Class 5 Tinned copper
outer-sheath LSZH
Temperature range Fixed Installation – 20 °C / + 70 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class B2CA
IEC / EN standard EN50363-7 / EN60332-3-24 / EN60754-1 / EN 61043
-
1x6mm2 SIF 300/500V
Conductor Tinned Copper, Class 5
Insulation Silicone Rubber
Nominal Voltage 300/500V
Working Temperature -60°C up to +180°C
-
1x70mm2 Athiflex PVC Black 450/750V
Conductor Extreme flexible copper conductor
outer-sheath PVC TM2
Temperature range Operating temperature – 20 °C / + 70 °C
nominal-voltage-uo-u 450/750V
UV resistant No
IEC / EN standard EN 50363-4-1 / IEC 60332-1-2
-
1x70mm2 Athiflex PVC Red 450/750V
Conductor Extreme flexible copper conductor
outer-sheath PVC TM2
Temperature range Operating temperature – 20 °C / + 70 °C
nominal-voltage-uo-u 450/750V
UV resistant No
IEC / EN standard EN 50363-4-1 / IEC 60332-1-2
-
1x70mm2 H01N2-D Black
Conductor Flexible copper conductor
outer-sheath Rubber EM5
Temperature range Fixed Installation – 20 °C / + 85 °C
nominal-voltage-uo-u 100V
UV resistant Yes
IEC / EN standard EN-50525-2-81 / IEC 60332-1-2
-
1x70mm2 H07RN-F Black
Conductor Flexible Class 5 bare copper
outer-sheath Rubber
Temperature range Fixed Installation – 25 °C / + 55 °C
nominal-voltage-uo-u 450/750V
UV resistant Yes
CPR class Eca
IEC / EN standard EN 50525-2-21 / IEC 60332-1-2 VDE 0482-332-1-2
-
1x70mm2 H07Z1-R Green/Yellow B2CA
Conductor Stranded Class 2 bare copper
outer-sheath LSZH
Temperature range Fixed Installation – 20 °C / + 70 °C
nominal-voltage-uo-u 450/750V
UV resistant No
CPR class B2CA
IEC / EN standard EN 60228 / EN 50363-7 / EN13501-6 /
-
1×95/16mm2 (N)A2XS(F)2Y BLACK 12/20KV
Conductor Circular Stranded Compacted Aluminium (Class 2)
Conductor Screen Extruded Thermosetting Semi-Conducting Compound
Insulation XLPE
Insulation Screen Extruded Thermosetting Semi-conducting Compound (Bonded)
Metallic Screen Copper Tape Screen (Open Helix)
Water Blocking Tape Non-conductive Water Blocking Tape
Outer Sheath PE, Black
-
1x95mm2 (19×2.5) Bare copper
Conductor Bare copper stranded.
UV resistant No
IEC / EN standard EN 7885
-
1x95mm2 Athiflex PVC Black 450/750V
Conductor Extreme flexible copper conductor
outer-sheath PVC TM2
Temperature range Operating temperature – 20 °C / + 70 °C
nominal-voltage-uo-u 450/750V
UV resistant No
IEC / EN standard EN 50363-4-1 / IEC 60332-1-2