241–256 van de 282 producten gevonden
-
H01N2-D 1x25mm2 RED
Conductor Flexible copper conductor
outer-sheath Rubber EM5
Temperature range Fixed Installation – 20 °C / + 85 °C
nominal-voltage-uo-u 100V
UV resistant Yes
IEC / EN standard EN-50525-2-81 / IEC 60332-1-2
-
H01N2-D 1x35mm2 RED
Conductor Flexible copper conductor
outer-sheath Rubber EM5
Temperature range Fixed Installation – 20 °C / + 85 °C
nominal-voltage-uo-u 100V
UV resistant Yes
IEC / EN standard EN-50525-2-81 / IEC 60332-1-2
-
H01N2-D 1x50mm2 RED
Conductor Flexible copper conductor
outer-sheath Rubber EM5
Temperature range Fixed Installation – 20 °C / + 85 °C
nominal-voltage-uo-u 100V
UV resistant Yes
IEC / EN standard EN-50525-2-81 / IEC 60332-1-2
-
H01N2-D 1x70mm2 RED
Conductor Flexible copper conductor
outer-sheath Rubber EM5
Temperature range Fixed Installation – 20 °C / + 85 °C
nominal-voltage-uo-u 100V
UV resistant Yes
IEC / EN standard EN-50525-2-81 / IEC 60332-1-2
-
H01N2-D 1x95mm2 RED
Conductor Flexible copper conductor
outer-sheath Rubber EM5
Temperature range Fixed Installation – 20 °C / + 85 °C
nominal-voltage-uo-u 100V
UV resistant Yes
IEC / EN standard EN-50525-2-81 / IEC 60332-1-2
-
JE-H(st)H – Bd FE180 / E30-E90 – 1x2x0,80+0,80mm Orange B2CA
Conductor Bare solid copper wire ( Class 1 )
outer-sheath LSZH
Temperature range Fixed Installation – 30 °C / + 70 °C
UV resistant No
CPR class B2CA
IEC / EN standard EN 61034 / EN 50267 / IEC 60332-3-24 Cat C
-
JE-H(st)H – Bd FE180 / E30-E90 – 4x2x0,80+0,80mm Orange B2CA
Conductor Bare solid copper wire ( Class 1 )
outer-sheath LSZH
Temperature range Fixed Installation – 30 °C / + 70 °C
UV resistant No
CPR class B2CA
IEC / EN standard EN 61034 / EN 50267 / IEC 60332-3-24 Cat C
-
Li-H(St)H ALARM 4×0.22 LSZH White Cca
Conductor Bare copper stranded
outer-sheath PVC
Temperature range Fixed Installation – 15 °C / + 70 °C
nominal-voltage-uo-u 250 / 500 V
UV resistant No
CPR class CCA
IEC / EN standard EN 50363-7 / EN 60332-3 / EN 50267-2-1
-
Li-H(St)H ALARM 6×0.22 LSZH White Cca
Conductor Bare copper stranded.
outer-sheath PVC
Temperature range Fixed Installation – 15 °C / + 70 °C
nominal-voltage-uo-u 250 / 500 V
UV resistant No
CPR class CCA
IEC / EN standard EN 50363-7 / EN 60332-3 / EN 50267-2-1
-
Li-H(St)H ALARM 8×0.22 LSZH White Cca
Conductor Bare copper stranded.
outer-sheath PVC
Temperature range Fixed Installation – 15 °C / + 70 °C
nominal-voltage-uo-u 250 / 500 V
UV resistant No
CPR class CCA
IEC / EN standard EN 50363-7 / EN 60332-3 / EN 50267-2-1
-
LIHCH – 2×1.0mm2 – B2CA
Conductor Flexible Class 5 bare copper
outer-sheath HFFR
Temperature range Fixed Installation – 30 °C / + 70 °C
nominal-voltage-uo-u 300/500V
UV resistant No
CPR class B2CA
IEC / EN standard EN 60332-1-2 / EN 60228 – EN 50290-2-22
-
LIHCH – 2×1.5mm2 – B2CA
Conductor Flexible Class 5 bare copper
outer-sheath HFFR
Temperature range Fixed Installation – 30 °C / + 70 °C
nominal-voltage-uo-u 300/500V
UV resistant No
CPR class B2CA
IEC / EN standard EN 60332-1-2 / EN 60228 – EN 50290-2-22
-
LIHCH – 3×1.5mm2 – B2CA
Conductor Flexible Class 5 bare copper
outer-sheath HFFR
Temperature range Fixed Installation – 30 °C / + 70 °C
nominal-voltage-uo-u 300/500V
UV resistant No
CPR class B2CA
IEC / EN standard EN 60332-1-2 / EN 60228 – EN 50290-2-22
-
LIHCH – 4×1.5mm2 – B2CA
Conductor Flexible Class 5 bare copper
outer-sheath HFFR
Temperature range Fixed Installation – 30 °C / + 70 °C
nominal-voltage-uo-u 300/500V
UV resistant No
CPR class B2CA
IEC / EN standard EN 60332-1-2 / EN 60228 – EN 50290-2-22
-
LIHCH – 5×1.5mm2 – B2CA
Conductor Flexible Class 5 bare copper
outer-sheath HFFR
Temperature range Fixed Installation – 30 °C / + 70 °C
nominal-voltage-uo-u 300/500V
UV resistant No
CPR class B2CA
IEC / EN standard EN 60332-1-2 / EN 60228 – EN 50290-2-22
-
LIHH – 2 x 0.75mm2 – CCA
Conductor Flexible Class 5 bare copper
outer-sheath HFFR
Temperature range Fixed Installation – 30 °C / + 70 °C
nominal-voltage-uo-u 300/500V
UV resistant No
CPR class CCA
IEC / EN standard EN 60332-1-2 / EN 60228 – EN 50290-2-22