Earth cable
The Halogen-free H07Z1-K is a flexible green/yellow installation or earth cable.
This H07Z1-K cable is ideal for installations in low-voltage installations, residential or commercial construction.
Due to the UV resistance, tinned copper conductor and very high CPR standard (B2CA), this cable can also be used for outdoor installations or installations in places where a high CPR fire class is required.
These cables are standard packed in nice handy 100 meter boxes or in 500 or 1000 meter reels.
For large projects, we can even supply reels on 5 Kilometers if that is a specific request.
Please feel free to ask any questions contact us.
See the datasheet for more specifications.
Featured products

1×10 mm2 H07Z1-K Green/Yellow Tinned and UV resistant B2CA
Conductor | Flexible Class 5 Tinned copper |
---|---|
outer sheath | LSZH |
temperature range | Fixed Installation – 20 °C / + 70 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | B2CA |
IEC / EN standard | EN50363-7 / EN60332-3-24 / EN60754-1 / EN 61043 |

1×35 mm2 H07Z1-K Green/Yellow Tinned and UV resistant B2CA
Conductor | Flexible Class 5 Tinned copper |
---|---|
outer sheath | LSZH |
temperature range | Fixed Installation – 20 °C / + 70 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | B2CA |
IEC / EN standard | EN50363-7 / EN60332-3-24 / EN60754-1 / EN 61043 |

1x16mm2 H07Z1-K Green/Yellow Tinned and UV resistant B2CA
Conductor | Flexible Class 5 Tinned copper |
---|---|
outer sheath | LSZH |
temperature range | Fixed Installation – 20 °C / + 70 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | B2CA |
IEC / EN standard | EN50363-7 / EN60332-3-24 / EN60754-1 / EN 61043 |

1x4mm2 H07Z1-K Green/Yellow Tinned and UV resistant B2CA
Conductor | Flexible Class 5 Tinned copper |
---|---|
outer sheath | LSZH |
temperature range | Fixed Installation – 20 °C / + 70 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | B2CA |
IEC / EN standard | EN50363-7 / EN60332-3-24 / EN60754-1 / EN 61043 |

1x25mm2 H07Z1-K Green/Yellow Tinned and UV resistant B2CA
Conductor | Flexible Class 5 Tinned copper |
---|---|
outer sheath | LSZH |
temperature range | Fixed Installation – 20 °C / + 70 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | B2CA |
IEC / EN standard | EN50363-7 / EN60332-3-24 / EN60754-1 / EN 61043 |

1x6mm2 H07Z1-K Green/Yellow Tinned and UV resistant B2CA
Conductor | Flexible Class 5 Tinned copper |
---|---|
outer sheath | LSZH |
temperature range | Fixed Installation – 20 °C / + 70 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | B2CA |
IEC / EN standard | EN50363-7 / EN60332-3-24 / EN60754-1 / EN 61043 |

1x50mm2 H07Z1-K Green/Yellow Tinned and UV resistant B2CA
Conductor | Flexible Class 5 Tinned copper |
---|---|
outer sheath | LSZH |
temperature range | Fixed Installation – 20 °C / + 70 °C |
rated-voltage-uo-u | 450 / 750V |
UV resistant | Yes |
CPR class | B2CA |
IEC / EN standard | EN50363-7 / EN60332-3-24 / EN60754-1 / EN 61043 |